{"id":9752,"date":"2026-10-12T18:21:08","date_gmt":"2026-10-12T15:21:08","guid":{"rendered":"https:\/\/euroformat.com\/?p=9752"},"modified":"2026-10-14T09:40:12","modified_gmt":"2026-10-14T06:40:12","slug":"dveri-ei60-shho-potribno-znaty-pered-zamovlennyam","status":"publish","type":"post","link":"https:\/\/euroformat.com\/en\/dveri-ei60-shho-potribno-znaty-pered-zamovlennyam\/","title":{"rendered":"EI60 doors: what you need to know before ordering"},"content":{"rendered":"<p class=\"isSelectedEnd\"><strong>EI60 doors<\/strong> have a fire resistance rating in which E refers to integrity, I to thermal insulation, and 60 indicates the time in minutes. The required rating is determined by the project, so before ordering it is important to check the requirements and documentation for the specific product.<\/p>\n<h2>What EI60 means<\/h2>\n<p class=\"isSelectedEnd\">The EI60 designation describes the fire resistance of a door according to the E and I criteria for the period indicated by the number 60. It refers to the confirmed characteristics of the tested construction, not simply to the material from which the door is made.<\/p>\n<p class=\"isSelectedEnd\">This means that <strong>EI60 metal doors<\/strong> and standard metal doors are not the same thing. A metal construction alone does not confirm the corresponding fire resistance rating.<\/p>\n<h2>How EI60 differs from EI30<\/h2>\n<p class=\"isSelectedEnd\">The main difference in the designation is the time: EI30 indicates 30 minutes, while EI60 indicates 60 minutes. Both ratings use the E criterion for integrity and the I criterion for thermal insulation.<\/p>\n<p class=\"isSelectedEnd\">This does not mean that EI60 is automatically the correct choice for every building. The required rating should be selected according to the project requirements.<\/p>\n<h2>Where EI60 may be specified<\/h2>\n<p class=\"isSelectedEnd\">The specific application of <strong>EI60 fire-rated doors<\/strong> is determined by the project documentation rather than by a general list of building types. EI60 may be specified for areas with higher requirements for the duration of fire resistance, such as technical zones, evacuation routes or locations where the applicable requirements call for this particular rating. The final decision should be based on the project for the specific building.<\/p>\n<h2>Why the rating should not be increased or reduced independently<\/h2>\n<p class=\"isSelectedEnd\">The <strong>EI60 fire resistance rating<\/strong> is a project characteristic, not an equipment level where \u201chigher is always better\u201d. It should also not be reduced without appropriate justification.<\/p>\n<p class=\"isSelectedEnd\">If the documentation specifies EI60, this is the requirement that should be followed when selecting the product. Any changes should be considered in the context of the project.<\/p>\n<h2>Construction and configuration<\/h2>\n<p class=\"isSelectedEnd\">An EI60 door is a complete system consisting of the door leaf, frame, hardware and seals, tested in that specific configuration. Replacing individual elements with alternatives from another manufacturer without corresponding testing can call the declared fire resistance rating of the complete assembly into question.<\/p>\n<p class=\"isSelectedEnd\">For this reason, the configuration should be agreed with the manufacturer rather than altered independently.<\/p>\n<h2>Documentary confirmation<\/h2>\n<p class=\"isSelectedEnd\">The EI60 designation in a product name or commercial proposal should not be the only basis for selection. Before purchasing, the documentation confirming the declared rating of the specific construction should be checked.<\/p>\n<p class=\"isSelectedEnd\">The EI60 rating may be confirmed by a fire test report or certificate of conformity. Euroformat provides documentary confirmation of product characteristics, allowing the declared rating to be checked against the project requirements before installation and the relevant documents to be presented when the building is handed over.<\/p>\n<h2>Information required for ordering<\/h2>\n<p class=\"isSelectedEnd\">For accurate selection of EI60 doors, it is advisable to provide:<\/p>\n<ul data-spread=\"false\">\n<li>door opening dimensions;<\/li>\n<li>purpose of the room and the project requirements for the fire resistance rating;<\/li>\n<li>whether glazing or additional elements are required;<\/li>\n<li>opening direction and required configuration.<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The more accurate the information, the lower the risk of discrepancies with the project after installation.<\/p>\n<h2>Need doors that meet the project requirements?<\/h2>\n<p class=\"isSelectedEnd\">Provide <a href=\"https:\/\/euroformat.com\/en\/about\/\">Euroformat<\/a> specialists with the initial project data and the required fire resistance rating. This will help clarify the available product version and documentation for the specific order.<\/p>\n<h2>Frequently asked questions<\/h2>\n<h3>Is EI60 always better than EI30?<\/h3>\n<p class=\"isSelectedEnd\">No. \u201cBetter\u201d is not the right way to compare these ratings because they are intended for different project requirements rather than as stronger or weaker product grades. EI60 confirms a longer fire resistance period, but this does not automatically make it the correct choice where EI30 is sufficient. The required rating is determined by the applicable project requirements.<\/p>\n<h3>Who determines whether EI60 is required?<\/h3>\n<p class=\"isSelectedEnd\">The need for EI60 doors is defined in the project documentation on the basis of the applicable building requirements for the specific type of space. This decision is made by the project designers during the design stage rather than by the building owner or installation contractor. The customer should follow these requirements when selecting the doors.<\/p>\n<h3>Does EI60 affect the choice of door configuration?<\/h3>\n<p class=\"isSelectedEnd\">Yes. The declared rating is confirmed for a specific configuration consisting of the door leaf, frame, hardware and seals together. Replacing individual components with alternatives that have not been tested as part of the same construction may affect compliance with the declared rating. The configuration should therefore be agreed with the manufacturer rather than selected independently.<\/p>\n<h3>What documents confirm the declared characteristics?<\/h3>\n<p class=\"isSelectedEnd\">The declared fire resistance rating is confirmed by a fire test report or certificate of conformity issued by an accredited laboratory or certification body. These documents are provided by the manufacturer with the product. They, rather than the marking alone, provide the basis for confirming compliance with the project requirements.<\/p>\n<h2>Conclusion<\/h2>\n<p>EI60 is a fire resistance classification based on the E and I criteria with a duration of 60 minutes. This type of door should be selected not simply because the number in the designation is higher, but because the corresponding rating is required by the project. Before ordering, the configuration and documentation for the specific product should be checked.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>EI60 doors have a fire resistance rating in which E refers to integrity, I to thermal insulation, and 60 indicates the time in minutes. The required rating is determined by the project, so before ordering it is important to check the requirements and documentation for the specific product. What EI60 means The EI60 designation describes [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":9749,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[32],"tags":[],"class_list":["post-9752","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-test-category-1"],"acf":[],"_links":{"self":[{"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/posts\/9752","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/comments?post=9752"}],"version-history":[{"count":1,"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/posts\/9752\/revisions"}],"predecessor-version":[{"id":9754,"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/posts\/9752\/revisions\/9754"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/media\/9749"}],"wp:attachment":[{"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/media?parent=9752"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/categories?post=9752"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/euroformat.com\/en\/wp-json\/wp\/v2\/tags?post=9752"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}